dc.contributor.author | Kandemir Besek, Nilay | |
dc.contributor.author | Asık Nacaroglu, Senay | |
dc.contributor.author | Kırgız, Ahmet | |
dc.contributor.author | Ozturk Karabulut, Gamze | |
dc.contributor.author | Okmen, Helin | |
dc.contributor.author | Ahmet, Sibel | |
dc.date.accessioned | 2023-01-30T07:47:24Z | |
dc.date.available | 2023-01-30T07:47:24Z | |
dc.date.issued | 2023 | en_US |
dc.identifier.citation | Besek, N. K., Nacaroglu, S. A., Kırgız, A., Karabulut, G. O., Okmen, H., & Ahmet, S. (2023). Efficacy of keratometric values obtained from Sirius topographer® in nidek axial length-scan® for intraocular lens calculation after penetrating keratoplasty. Photodiagnosis and Photodynamic Therapy, 41, 103195. | en_US |
dc.identifier.issn | 1572-1000 | |
dc.identifier.uri | https://doi.org/10.1016/j.pdpdt.2022.103195 | |
dc.identifier.uri | https://hdl.handle.net/20.500.12294/3190 | |
dc.description.abstract | Background: To evaluate the accuracy of keratometric values obtained from Scheimpflug (Sirius) topography using Nidek AL-Scan optical biometry (OB) for intraocular lens (IOL) power calculating after penetrating keratoplasty (PK). Methods: Thirty eyes of 26 patients were included in this study. The demographic information, complete ophthalmic examination, IOL calculation technique, and its effect on final refractive results were evaluated. Results: The mean age of the patients was 52.76 ± 16.20 years. The mean K readings using Nidek AL-Scan OB, mean simulated K (SimK) (3mm), and mean pupillary power (MPP) (4.5mm) K readings using Sirius were 41.92 ± 5.05 D, 42.99 ± 5.78 D, and 43.30±6.23 D (p= 0.515). Conclusions: Both devices correctly calculated IOL power after PK; however, Sirius SimK (3mm) gave the lowest mean absolute error (MAE) results and can be safely used for IOL power calculation. © 2022 Elsevier B.V. | en_US |
dc.language.iso | eng | en_US |
dc.publisher | Elsevier | en_US |
dc.relation.ispartof | Photodiagnosis and Photodynamic Therapy | en_US |
dc.identifier.doi | 10.1016/j.pdpdt.2022.103195 | en_US |
dc.rights | info:eu-repo/semantics/closedAccess | en_US |
dc.subject | Cataract Surgery | en_US |
dc.subject | Optical Biometry | en_US |
dc.subject | Penetrating Keratoplasty | en_US |
dc.subject | Scheimpflug Topography | en_US |
dc.title | Efficacy of keratometric values obtained from Sirius topographer® in nidek axial length-scan® for intraocular lens calculation after penetrating keratoplasty | en_US |
dc.type | article | en_US |
dc.department | Tıp Fakültesi, Dahili Tıp Bilimleri | en_US |
dc.authorid | 0000-0003-0403-9749 | en_US |
dc.identifier.volume | 41 | en_US |
dc.relation.publicationcategory | Makale - Uluslararası Hakemli Dergi - Kurum Öğretim Elemanı | en_US |
dc.institutionauthor | Ozturk Karabulut, Gamze | |
dc.authorscopusid | 56180319800 | en_US |
dc.identifier.scopus | 2-s2.0-85145747196 | en_US |